Description

FST 3561 Power Quality Analyzer
Smart measurement and analysis

For 3-phase/4-wire system

FST 3561 is a 3-phase testing and analyzing device for the quality of power grid. It provides multiple analyzing for electric harmonic, swell/dip, flicker, 3-phase unbalance, power and energy, surge and so on.


Why FST?

An Easy-to-use power quality tools is a ”must-have” for any person who maintains or troubleshoots three phase power. FST three-phase power quality meters help you locate, predict, prevent and troubleshoot problems in power distribution systems. We offer a full range of trouble-shooters for the prevention and analyzing of the power quality problem. It is not only your problem solver, but also money saver.

Functional Displays

Volts/Amps/Hertz Harmonics Power/Energy

Unbalance Dips/Swells Fluctuation/Flicker

Test record Oscilloscope Data management

Technical Parameter

¨ LCD: 5.7” 320 x 240 TFT touch screen

¨ Input Impedance: 1MΩ20pF

¨ Measurement Range: Vrms 10700V

¨ Arms:5A, 10A, 100A, 1000A, 1500A and 3000A
(with relative current clamps)

¨ Frequency: 40Hz70Hz

¨ Harmonic Measurement: 050th harmonics

¨ Inrush Current: 2000A

¨ Peak Voltage: 1000V

¨ Internal Memory: 128MB

¨ Communication Port: USB

¨ N.W.(main unit): 1.6 kg (3.53lb)

¨ Battery: durable for 5 hours after full charge

Typical Applications

¨ Trouble-elimination: fast measurement and display on screen for trouble-shooting

¨ Predictive maintenance: test to avoid power quality problem before malfunction happens

¨ Service function: measurement for power quality before users lead-in

¨ Long time analysis: recording function help find out unobvious and occasional malfunction

¨ Load analysis: check quality of electric system before adding loads

¨ Energy evaluation: evaluate energy consumption before installation of energy-saving facilities

Specification

Specifications

Range

Accuracy

Volt/Amp/Hertz

Volt: 10~700V (true rms)

Amps: 0.5~3000A (true rms, with relevant current clamp) N current: 0.5~25A (true rms)

Hertz: 40~70Hz

Volts: ±0.5%

Amps: ±0.5%

Hertz: ±0.01Hz

NOTE: Take frequency of Phase A as total testing frequency.

Harmonic

Volts: total harmonic +1~50th

Amps: total harmonic +1~50th

Volts: ±0.1(%r)

Amps: ±0.05 (A)

Power testing

Active Power: 0.05~700KW

Apparent Power: 0.05~700KVA

Reactive Power: 0.05~700KVAR

Power Factor: 0.00~1.00

Active Energy: 0.01~10000kWh

Apparent Energy: 0.01~10000kVAh

Reactive Energy: 0.01~10000kVARh

Average Power Factor: 0.00~1.00

Active Power: indication±50W

Apparent Power: indication±50VA

Reactive Power: indication±50VAR

Power Factor: indication±0.05

Active Energy: indication±0.05kWh

Apparent Energy: indication±0.1 kVAh

Reactive Energy: indication±0.1 kVARh

Average Power Factor: indication±0.005

Unbalance

Fundamental Volts: 10~700V (true rms)

True Amps: 0.5~1000A (True rms)

Fundamental Hertz: 40~70Hz

Phase Angle: 0~360o

Unbalance: 0.0%~100%

Volts: ±0.5%

Amps: ±0.5%

Hertz: indication±0.01Hz

Phase Angle: indication±0.3 o

Volt unbalance: indication ±0.2%

NOTE: Take frequency of Phase A as total testing frequency.

Data Recording

Recording for: 3 phase voltage, current, null current, voltage harmonic (THD and 1~50 harmonics), current harmonics ( THD and 1~50 harmonics), unbalance, KW, PF, flicker and fluctuation

Time interval: 3s~30m adjustable

Time duration: <960 hours

Sags(Dips)/Swells

Volts sag, Volts Swells and instant interruption

Maximally could record 40 times

Fluctuation

Voltage Fluctuation:0.1%~10.0%

±5%

Flicker

Short-time and long-time flicker

Short-time: ±5%

Scope

3-phase Volts, 4-wire Current, null volt and null current waveform

Max Hertz: 200KHz Min Hertz: 100Hz


Featured Suppliers: