- Optical, Photographic, Cinematographic, Measuring, Checking, Precision, Medical Or Surgical Instruments And Apparatus; Parts And Accessories Thereof
- Apparatus Based On The Use Of X-rays Or Of Alpha, Beta Or Gamma Radiations, Whether Or Not For Medical, Surgical, Dental Or Veterinary Uses, Including Radiography Or Radiotherapy Apparatus, X-ray Tubes And Other X-ray Generators, High Tension Generators, Control Panels And Desks, Screens, Examination Or Treatment Tables, Chairs And The Like.
- Apparatus Based On The Use Of X-rays (other Than For Medical, Surgical, Dental Or Veterinary Uses)
Industrial Pipe Weldings Inspection Equipment
Product Images
Product Property
model : | YG-100D |
X-ray Tube Inserted : | Glass X-ray Tube |
Manufacturer : | Dandong Yangguang(DDYG) |
Product Status : | New |
Sample Available : | no |
Shipment Terms : | fob |
Payment Mode : |
T/T |
Description
Technical Data(YG-100D X-ray Pipeline Crawler)
According to the service condition of domestic pipeline crawler and feedback from inspection companies, we completely improved the original circuit and detector operating circuit, which makes our pipeline crawler easier to operate and more humanizative. This embodies the customer first and people oriented manufacturing concept of DDYG.
This is a new design of pipeline crawler, which is totally different from old design in circuit (Please refer to the Operation Manual). New YG-100D X-ray Pipeline Crawler is wildly used to welding quality inspection of long pipeline with the characters of high efficiency, excellent Tran illumination, and high imaging sensitivity, as well as security, reliability and convenience.
Item | Parameter | |
Model | YG-100D | |
Range of Pipe Diameter | Φ219mm—Φ510mm | |
Max. Penetration (A3 Steel) | 16mm | |
Max. Output Voltage of Tube | 160Kv | |
Max. Output Current of Tube | 3mA | |
Tube (Cone) | Focal Size | 1.0×2.0mm |
Beam | 360°×38° | |
Environment Temperature | -40°~ 70° | |
Relative Humidity | ≤90% | |
Energy Capacity of Battery | 110V, 10Ah | |
Motor Power | 150W Continuous | |
Delay before Exposure | 24s | |
Exposure Time (can be timed outside pipe) | 1~300s(Continuously Adjustable) | |
Crawling Ability | ≤27° | |
Location Accuracy | ±5mm | |
Crawling Distance | 5Km | |
Crawling Speed | 15m/min~18m/min | |
Turning Radius | ≥7D | |
Total Weight | 54.1Kg |