QINGDAO CHINA

Qingdao An International Business City.

maternal monitor

Product Images

  • maternal monitor

Product Property

Product Status : New
Sample Available : yes
Shipment Terms : fob
Payment Mode : T/T,L/C

Description

Maternal and child monitor PM-9000E+

ECG and heart rate / noninvasive blood pressure / blood oxygen / temperature / respiratory / fetal heart rate and uterine pressure / fetal movement mark / tape printing

features:

1, most precise for using the world famous module

2, the waveform is most clear for it uses the 8.4 inch colorful LCD TEF which has the strong brightness and high resolution.

3, rotating shuttle operation, and the screen can be used in both english and Chinese , therefore, it is easy to learn and operate.

4, it can show the ECG at the same time

5, the ECG waveform can be replayed every five minutes and the ST part can be checked by itself.

6, it can memorize the data and catches the mobile waveform

7, the limit for the alarm can be set by yourself, and alarming both in sound and light.

8, it can be used for adults, children, and new born baby.

9, it is anti-interference for electric knife

10, it is widely used in internal medicine, surgery, obstetrics and gynecology department, Pediatrics, first-aid, ICU, and CCU.

It's parameters:

Size: 320mm×1800mm×270mm

Weight: 3.0kg

Screen: 12.1inch colorful liquid TFT LCD

Resolution: 800×600

Security standard: IEC601-1, UL2601

Heartbeat rate of fetus:

The probe: the nine wafer, the wide beam, work like pulse, high sensitivity

The power of Ultrasonic wave : lower than 1 MW / cm2

The frequency of it's work: 1.0MHZ

How to handle the signal: Digital signal processing unit

Maximum audio power output: 1.5w

Contraction stress:

The range of measurement: 20~100 pressure unit

The Ultrasonic output of the probe:

According to the rule set in 1992, the negative peak of sound pressure should be less than 1MPa, the Acoustic beam and the sound intensity should be less than 20 MW/cm2, the instant average peak of the sound intensity should be less than 100 MW/cm2. The sound intensity of this monitor is less than 1MW/cm2.

The GEL:

Viscous water-based compound, no harm to the skin, no allergy, stable, and anti-bacteria.

ECG:

Gain option: four gears including ×1 、×2 、×4、×0.5

Calibration signal: 1mV

Common mode signal suppression: greater than 70dB

Accuracy of heartbeat: ±5 times/minute

Scan rate:12.5 mm / S, 25 mm / S, 50 mm / S three standard file

ST segment detection: range-2.0mV----+2.0mV

Bandwidth:0.5HZ~100HZ

Lead: total lead, I, II, III, avF, avR, avL, V1-V6

Using standard: Conform to the standard of ANSI/AMI EC13-1992

Responding time:1s

Way of alarming: both in sound and light

Heart rate alarm preset range:upper limit, 1~255times/minute

Lower limit, 0~254times/minute

NIBP:

Technic:display waveform

Working mode:manual or automatic

Measuring unit:Mm hg / Kpa

Security for overpressure:double way for secure

Deviation between each period:choose in 2510153060minutes.

Time taking:less than 45s

Pressure range in cuff: 0 250 mmHg

Precision of blood pressure:according to the ANSI / AAMI SP10 made in 1992.

Original cuff inflation: 180 mmHg(new born 70mmHG, little child 120mmHg)

Cuff Subsequent inflation: original Systolic pressure + 30 mmHg

Range of blood pressure measurement:

Systolic pressure: 60 250 mmHg

Diastolic pressure: 40 220 mmHg

Average pressure:45 235 mmHg

Responding time:1s

Way of alarm;light and sound

Preset alarm limit:

Upper limit of Systolic pressure: 1 255 mmHg

Lower limit: 0 254 mmHg

Upper limit of Diastolic pressure: 1 255 mmHg

Lower limit:0 254 mmHg

SPO2 :

Range: 0~100%

Resolution: 1%

The times of pulse: 20~250times/minute

Precision: 70% 100 % ±2%

Range of alarm:

Upper limit:1%~100%

Lower limit:0%~99%

TEMP:

Technic: High sensitive thermistor probe

It's range :20℃—45

Resolution: 0.1%

Precision:±0.1

Range of alarm:

Upper limit: 20.1℃ - 45.5

Lower limit: 20℃ - 45.4

RESP:

Breathing frequency: 0~60/minute

Precision: ±1bpm

Responding time:1s

Gain option: four gears including ×1 、×2 、×4、×0.5

Way of alarm:light and sound

Range of alarm:

Upper limit:10~100times/minute

Lower limit:0~99times/minute

Tendency diagram:

Type: table/form

Storage:48hours

The interval between data: 30seconds

Mode of form:all parameters have tendency

Mode of table: 11kinds of content in every line, 15 lines on each page


Featured Suppliers:

A glove for every situation,cut resistance,chemical resistance, or disposable gloves