Standard ultrasound test sieve

Product Images

  • Standard ultrasound test sieve

Product Property

Product Status : New
Sample Available : yes
Shipment Terms : Negotiable
Payment Mode : Negotiable

Description

Overview:
Ultrasound screening system is a simple, practical and reliable screening system, is the most effective solution mesh clogging. It can be widely used in pharmaceutical, metallurgy, chemical, mineral, food and other industries require sophisticated screening filter, screening high filtration precision, effectively address the reunion, static, strong adsorption jam mesh screening problems, etc., is the screen a major breakthrough in technology sub-sectors.

Structure:

Ultrasonic shaker Power: 38KHZ ultrasonic high frequency power supply. Built-in microcomputer chip, depending on the state of the material can be full digital frequency automatic tracking, without manual adjustment, easy to operate. Long working transducer low heat, stable working condition.
● HF connecting cables: using an ultrasonic transducer cable is connected with the power supply between the ultrasonic vibration sieve.
Connectors: air connector plug.
Transducer: High-performance ultrasonic transducer devices.
ultrasonic grid: from the outside grid resonator components.
Screen: Suitable for 10 mesh to 635 mesh.

How it works:
Ultrasound screening system by ultrasonic vibration power, HF connection cable, transducer, resonator components. High frequency electric power generated by the ultrasonic vibration sieve by the transducer is converted into a high frequency sinusoidal in the form of longitudinal shock wave, which shock waves transmitted on the resonator so that the resonator resonance, the resonator is then uniformly transferred to the vibrating screen surface. Mesh material to do the low-frequency vibrations, while three dollars, superimposed ultrasonic vibrations, can prevent clogging, but also improve the yield and screening accuracy.
Technical parameters:
Ultrasonic shaker Power:
Power input: AC220V ± 10% 50 ~ 60Hz
Machine current: ≤0.6A
High-frequency currents: ≤0.4A
Operating frequency: 38KHz
Operating modes: continuous, pulse
Ambient temperature: -10 ~ 35 ℃

Instructions for use:
1. First, the transducer is locked on the network posted a good grid (locking force of 40 ~ 50kg), then the ultrasonic vibration sieve into the grid.
2. The ultrasonic vibration and vibration sieve sieve power supply respectively, for the three-phase supply vibration sieve, ultrasonic vibrating screen-phase power supply for but both need to be grounded.
3. After ultrasonic vibration sieve OUT ultrasonic output power panel, please insert the ultrasound HF cable lock, and check the connection is reliable. HF aerial connection cable plug the other end of the transducer is connected, and to ensure that the seal securely.
4. Connect the power supply ultrasonic shaker and ultrasonic HF connection cable, check and correct on ultrasonic power. As soon as "drip" sound, ultrasonic shaker start, the display window shows "vibration amplitude XXXμm", and enter the self-test status. By adjusting the amplitude of the knob, you can adjust the vibration amplitude (recommended vibration amplitude 30 ~ 100μm, is conducive to screen life).
5. There are two kinds of ultrasonic resonant power supply working condition: Continuous "-" Work status and pulse ", " working condition, normal continuous "-" Work state. Continuous "-" working condition, press mode key to enter pulse "system". In the pulse "" I continuously work status button to return to continuous operation.

Other considerations:
Before using ultrasonic vibration system, please read this notice carefully, follow the instructions to avoid unnecessary damage to the device.
An ultrasonic vibrating screen power supply input voltage is AC 220V.
2. In the case to meet the production requirements, the vibration amplitude should not exceed 200μm.
3. That no load grid when the grid is no stretching, do not open the power ultrasonic vibration sieve. Otherwise, it is likely to cause the power grid and the overcurrent and transducer damage.
4. The screen must be taut, otherwise affect output and ultrasonic vibration effects.
5. transducer aviation butt plug screw must be tightened, and wrapped with insulating tape to prevent dust. Attention to the protection of this connection is in use.
6. Check the machine before starting the transducer and cable plug locking nut is, whether the transducer and grid lock (locking force of 40 ~ 50kg). In use, the note between the chassis and the transducer cable connection protection HF, HF connection cables and transducers socket should pay attention to moisture, water connection plugs and sockets are not allowed.
7. If a conductive material, please use an extension cable to connect ultrasonic HF, the ultrasonic vibration sieve screening site power supply and isolated to prevent the material from entering the power box causing a short circuit.
8. Replace the mesh, grid inner glue residue (resonator) on the wallpaper with a sharp Daogua go, do not use the angle grinder grinding wheel to prevent the destruction of the resonator.
9. Each ultrasound system includes an ultrasonic vibrating screen power supply, an HF connection cable, a transducer, a grid. Do not use with other manufacturers of ultrasound systems to each other, so as to avoid unnecessary losses.
10. Recommends 504 network using glue stick, glue try to book mesh, mesh surface tension should be uniform (it is necessary to be able to adopt tonometer Monitoring Network surface tension).