- Nuclear Reactors, Boilers, Machinery And Mechanical Appliances; Parts Thereof
- Air Or Vacuum Pumps, Air Or Other Gas Compressors And Fans; Ventilating Or Recycling Hoods Incorporating A Fan, Whether Or Not Fitted With Filters.
- Fans (excl. Table, Floor, Wall, Window, Ceiling Or Roof Fans, With A Self-contained Electric Motor Of An Output <= 125 W)
turbine ventilator , turbo ventilator, roof ventil
Product Images
Product Property
Product Status : | New |
Sample Available : | yes |
Shipment Terms : | fob,cfr,cif,Negotiable |
Payment Mode : |
L/C,cash,Credit Card,PayPal,WesternUnion |
Description
Roof Turbine Ventilators
6"8"10"12"20"24"27"35"
Model 6"8"10"12"20"24"27"35" Materials Adopting several kinds of raw materials to make roof turbine ventilators including aluminum alloy, stainless steel , color steel, aluminum alloy with fluorine carbon polyester coating and so on . Benefits Light weight, high revolving speed, strong corrosion resistance, high air exhausting efficiency, sturdy and durable, clean and smooth, uniform color, and easy maintenance. Working Condition Temperature difference between indoor and outdoor is 0.45, It begins to revolve at the wind speed of 0.12m/ s. Roofing Angle Applied in different roofing in the scope of 0-22.5°oblique angle. Warranty 15 years Applicable scope Industrial workshop, commercial and civil housing. Origin of product China
Ventilation quantifying Ventilation quantity=Cubage of building x Exchange times per hour / Exchange ability of single ventilator Cubage of building=Length x Width x Height Exchange times per hour : it is subject to building function
Building sorted by function | Exchange times per hour |
Gymnasium, Swimming pool | 3~8 |
Warehouse | 4~12 |
Printery | 5~12 |
Chemical plant | 8~18 |
High temperature plant | 12~18 |
Textile plant | 12~20 |
Wind speed | 9.6 km/h | 12.8 km/h | ||||||
Temperature difference | 5 | 10 | 15 | 5 | 10 | 15 | ||
Model | Height of eaves | Exchange ability of single turbine ventilator | ||||||
6”(150mm) | 9m | 705 | 790 | 850 | 880 | 960 | 1040 | |
12m | 780 | 825 | 900 | 910 | 1020 | 1080 | ||
8”(200mm) | 9m | 940 | 1060 | 1140 | 1180 | 1280 | 1390 | |
12m | 1040 | 1100 | 1190 | 1225 | 1360 | 1440 | ||
10”(250mm) | 9m | 1175 | 1320 | 1420 | 1470 | 1610 | 1740 | |
12m | 1300 | 1370 | 1480 | 1520 | 1690 | 1810 |
Exchange ability(cubic meter per hour) | |||||||
Wind speed | 3.2km/h | 6.4 km/h | 8km/h | ||||
Temperature difference | 5 | 10 | 5 | 10 | 5 | 10 | |
Height of eaves | 6m | 648 | 791 | 976 | 1118 | 1170 | 1312 |
9m | 726 | 897 | 1053 | 1224 | 1246 | 1419 | |
12m | 791 | 987 | 1118 | 1315 | 1312 | 1511 |
Exchange ability(cubic meter per hour) | |||||||
Wind speed | 6km/h | 8 km/h | 10 km/h | ||||
Temperature difference | 5 | 10 | 5 | 10 | 5 | 10 | |
Height of eaves | 6m | 2118 | 2508 | 2779 | 2918 | 3081 | 3219 |
9m | 2280 | 2730 | 3070 | 3142 | 3359 | 3478 | |
12m | 2416 | 2930 | 3234 | 3332 | 3636 | 3750 |
Exchange ability(cubic meter per hour) | |||||||
Wind speed | 6km/h | 8 km/h | 10 km/h | ||||
Temperature difference | 5 | 10 | 5 | 10 | 5 | 10 | |
Height of eaves | 6m | 3118 | 3508 | 3779 | 3918 | 4081 | 4219 |
9m | 3280 | 3730 | 4070 | 4142 | 4359 | 4478 | |
12m | 3416 | 3930 | 4234 | 4332 | 4636 | 4750 |
Exchange ability(cubic meter per hour) | |||||||
Wind speed | 3.2km/h | 6.4 km/h | 8km/h | ||||
Temperature difference | 5 | 10 | 5 | 10 | 5 | 10 | |
Height of eaves | 6m | 1615 | 2005 | 2337 | 2695 | 2763 | 3105 |
9m | 1827 | 2286 | 2547 | 3045 | 2972 | 3431 | |
12m | 2010 | 2529 | 2718 | 3245 | 3148 | 3675 |
Exchange ability(cubic meter per hour) | |||||||
Wind speed | 6km/h | 8 km/h | 10 km/h | ||||
Temperature difference | 5 | 10 | 5 | 10 | 5 | 10 | |
Height of eaves | 6m | 4118 | 4508 | 4779 | 4918 | 5081 | 5219 |
9m | 4280 | 4730 | 5070 | 5142 | 5359 | 5478 | |
12m | 4416 | 4930 | 5234 | 5332 | 5636 | 5750 |