24kV Silicone Rubber Fuse Cutout

Product Images

  • 24kV Silicone Rubber Fuse Cutout

Product Property

Product Status : New
Sample Available : no
Shipment Terms : fob
Payment Mode : T/T,L/C,PayPal,WesternUnion

Description

24kV Silicone Rubber Fuse Cutout

Description & Application

24kV silicone rubber fuse cutout is installed on the distribution transformer or pole of power line for overload protection and load current switching on/off. It is composed of a main insulating & conducting structure and a fiber glass arcing tube. The stationary contacts are fixed at both ends of the insulating post and moving contacts at both ends of fuse tube, with an arcing chamber and elastic auxiliary contacts to interrupt load current and capacitor current.

Technical Parameter & Detail Show

Technical Parameter

Item Unit Data
Rated Voltage kV 24
Rated Continuous Operating Current A 100200
Rated Frequency Hz 50/60
Rated Fuse Base Current A 100200
Rated Short-circuit Breaking Current kA 10kA, 12.5kA(4time for 100A, 1time for 200A)
Rated Power Frequency Withstand Voltage (dry/wet) kV 65/60
Rated Lightning Impulse Withstand Voltage(phase to earth/across the isolating distance kV 150/165
Creepage-distance mm 600(Porcelain)
744(Silicone Rubber)
Mechanical Life(continuous switch on-off) times 1000Unload Type
300Load Type
Elevation m 2000
Ambient Temperature -40 +70

Material

1. Fuse tube - epoxy fiber glass with fiber lining coated with special ultraviolet resistant material, the disconnecting switch blade can be here selected.

2. Upper contact - silver to silver, high contact pressure squeezed by stainless steel spring.

3. Trunnion - high strength cast copper, silver plated, and pressed on the side surface of the hinge to ensure the fuse tube alignment while switching-on.

Packing

Each in a poly bag, then in a five corrugated carton with poly foam inside

Feature & Advantages

The design and test of 24kV silicone rubber fuse cutout is complied with the following stand

1.The insulator fixing stem is fixed into insulator with white cement imported from America, together with tower structure it is very firm and quite suitable for outdoor application

2.The key mechanical parts are made of high quality brass, bronze and copper, supplying a longer life.

3.Conductive parts are all with silver plated pure copper or beryllium bronze, the thickness reaches as much as 20μ, reducing contact resistance and supplying a stronger conductive performance.

Standard & Certificates

The design and test of 24kV silicone rubber fuse cutout is complied with the following standards:

1.ISO9001

2.IEC282.1 IEC787

3.ANSI C37.41-94 ANSI C37.42-94

4.GB 15166.3-2008 GB311.1-97

5.DL/T 640-97 DL/T 593-96