- Optical, Photographic, Cinematographic, Measuring, Checking, Precision, Medical Or Surgical Instruments And Apparatus; Parts And Accessories Thereof
- Direction Finding Compasses; Other Navigational Instruments And Appliances.
- Navigational Instruments And Apparatus (excl. For Aeronautical Or Space Navigation, Compasses And Radio Navigational Equipment)
A160XT Triaxis Accelerometer
Product Images
Product Property
Product Status : | New |
Sample Available : | yes |
Shipment Terms : | fob |
Payment Mode : |
T/T |
Description
DESCRIPTION
The model A160XT is a multi-purposeaccelerometers. It combines and integrated high performancesensor chip and advanced circuit technology processing which makes it with very low noise as100ug(root Hz).
FEATURES
l±1g to ±200g range
lExcellent bias stability (less than 0.05% of full)
lSingle power supply
lLow power
lIndividually calibrated
lBrown out protected
lDemonstrated high reliability
APPLICATIONS
VibrationAnalysis
TiltMeasurement
MachineControl
AlarmSystem
VibrationMonitoring
Robotics
Instrumentation
SPECIFICATIONS
| Units | A1601T | A1602T | A1605T | A1610T | A1630T | A1650T | A1612T | A1621T |
Full scale range | g | ±1g | ±2g | ±5g | ±10g | ±30g | ±50g | ±100g | ±200g |
Bias calibration | mg | <5 | <10 | <25 | <50 | <150 | <250 | <500 | <1000 |
One year bias stability@6000g | mg typ.(max.) | 0.75(<2.5) | 1.5(<5) | 3.75(<12.5) | 7.5(<25) | 22(<75) | 37.5(<125) | 75(<250) | 150(<500) |
One year bias stability@1000g | mg typ.(max.) | 0.15(<0.75) | 0.3(<1.5) | 0.75(<3.75) | 1.5(<7.5) | 4.5(<22.5) | 7.5(<37.5) | 15(<75) | 30(<150) |
Switch on/off repeatability | mg max. | <0.1 | <0.15 | <0.375 | <0.75 | <1.5 | <3.8 | <7.5 | <15 |
Bias temp. coefficient | mg/℃ typ. | <0.05 | <0.1 | <0.25 | <0.5 | <1.5 | <2.5 | <5 | <10 |
| mg/℃ max. | ±0.2 | ±0.4 | ±1 | ±2 | ±6 | ±10 | ±20 | ±40 |
Scale factor sensitivity(K1) | mV/g | 2000±8 | 1000±8 | 400±4 | 200±2 | 66.6±1 | 40±1 | 20±1 | 10±1 |
One year scale factor stability | ppm typ.(max.) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) |
Scale factor temp. coefficient | ppm/℃ typ. | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
| min./max. | -50/250 | -50/250 | -50/250 | -50/250 | -50/250 | -50/250 | -50/250 | -50/250 |
Input axis misalignment (Kp, Ko) | mrad max. | <10 | <10 | <10 | <10 | <10 | <10 | <10 | <10 |
| %max | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Resolution/Threshold(@1Hz) | mg max. | <0.05 | <0.1 | <0.25 | <0.6 | <1.7 | <2.8 | <5.5 | <11 |
Non linearity | % of FS max. | <1 | <0.8 | <0.8 | <0.9 | <0.9 | <0.9 | <1 | <1 |
| g max. | <0.01 | <0.02 | <0.04 | <0.09 | <0.27 | <0.50 | <1 | <2 |
Bandwidth | Hz | 0 to ≥100 | 0 to ≥100 | 0 to ≥100 | 0 to ≥100 | 0 to ≥100 | 0 to ≥100 | 0 to ≥100 | 0 to ≥100 |
Noise spectral density in band | μV/√Hz typ. | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 |
(0 ; 9kHz) | max. | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
Resonant frequency | kHz |
| 1.4 | 2.9 | 3.7 | 6.3 | 11 | 15 | 26 |