QINGDAO CHINA

Qingdao An International Business City.

A160XVS Single Accelerometer

Product Images

  • A160XVS Single Accelerometer

Product Property

Product Status : New
Sample Available : yes
Shipment Terms : fob
Payment Mode : T/T

Description

DESCRIPTION

The model A160XVS is a multi-purposeaccelerometers. It combines and integrated high performancesensor chip and advanced circuit technology processing which makes it with very low noise as100ug(root Hz).


FEATURES

l±1g to ±200g range

lExcellent bias stability (less than 0.05% of full)

lSingle power supply

lLow power

lIndividually calibrated

lBrown out protected

lDemonstrated high reliability


APPLICATIONS

VibrationAnalysis

TiltMeasurement

MachineControl

AlarmSystem

VibrationMonitoring

Robotics

Instrumentation


SPECIFICATIONS

Units

NA1602VS

NA1610VS

NA1630VS

NA1650VS

NA1612VS

NA1621VS

Full scale range

g

±2g

±10g

±30g

±50g

±100g

±200g

Bandwidth(5%)

Hz

0 to ≥250

0 to ≥1000

0 to ≥1000

0 to ≥1000

0 to ≥1000

0 to ≥1000

Bandwidth(3dB)

Hz

0 to ≥800

0 to ≥3000

0 to ≥3000

0 to ≥3000

0 to ≥3000

0 to ≥3000

Resonant frequency

kHz

1.3

2

4

5.1

7.2

11

Noise spectral density in band

μV/Hz typ.

25

25

25

25

25

25

(0 ; 4000Hz)

max.

27

27

27

27

27

27

Bias calibration

mg

<10

<50

<150

<250

<500

<1000

One year bias stability@6000g

mg typ.(max.)

1.5(<5)

7.5(<25)

22(<75)

37.5(<125)

75(<250)

150(<500)

Switch on/off repeatability

mg max.

<0.15

<0.75

<1.5

<3.8

<7.5

<15

Bias temp. coefficient

mg/ typ.

<0.1

<0.5

<1.5

<2.5

<5

<10

mg/ max.

±0.4

±2

±6

±10

±20

±40

Scale factor sensitivityK1

mV/g

1000±8

200±2

66.6±1

40±1

20±1

10±1

One year scale factor stability

ppm typ.(max.)

300(<1000)

300(<1000)

300(<1000)

300(<1000)

300(<1000)

300(<1000)

Scale factor temp. coefficient

ppm/ typ.

100

100

100

100

100

100

min./max.

-50/250

-50/250

-50/250

-50/250

-50/250

-50/250

Input axis misalignment (Kp, Ko)

mrad max.

<10

<10

<10

<10

<10

<10

%max

1

1

1

1

1

1

Resolution/Threshold(@1Hz)

mg max.

<0.1

<0.6

<1.7

<2.8

<5.5

<11

Non linearity

% of FS max.

<0.8

<1

<1

<1

<1

<1

g max.

<0.02

<0.09

<0.27

<0.50

<1

<2



Featured Suppliers: