- Optical, Photographic, Cinematographic, Measuring, Checking, Precision, Medical Or Surgical Instruments And Apparatus; Parts And Accessories Thereof
- Direction Finding Compasses; Other Navigational Instruments And Appliances.
- Navigational Instruments And Apparatus (excl. For Aeronautical Or Space Navigation, Compasses And Radio Navigational Equipment)
A160XVT Triaxis Accelerometer
Product Images
Product Property
Product Status : | New |
Sample Available : | yes |
Shipment Terms : | fob |
Payment Mode : |
T/T |
Description
DESCRIPTION
The model A160XVT is a multi-purposeaccelerometers. It combines and integrated high performancesensor chip and advanced circuit technology processing which makes it with very low noise as100ug(root Hz).
FEATURES
l±1g to ±200g range
lExcellent bias stability (less than 0.05% of full)
lSingle power supply
lLow power
lIndividually calibrated
lBrown out protected
lDemonstrated high reliability
APPLICATIONS
VibrationAnalysis
TiltMeasurement
MachineControl
AlarmSystem
VibrationMonitoring
Robotics
Instrumentation
SPECIFICATIONS
| Units | NA1602VT | NA1610VT | NA1630VT | NA1650VT | NA1612VT | NA1621VT |
Full scale range | g | ±2g | ±10g | ±30g | ±50g | ±100g | ±200g |
Bandwidth(5%) | Hz | 0 to ≥250 | 0 to ≥1000 | 0 to ≥1000 | 0 to ≥1000 | 0 to ≥1000 | 0 to ≥1000 |
Bandwidth(3dB) | Hz | 0 to ≥800 | 0 to ≥3000 | 0 to ≥3000 | 0 to ≥3000 | 0 to ≥3000 | 0 to ≥3000 |
Resonant frequency | kHz | 1.3 | 2 | 4 | 5.1 | 7.2 | 11 |
Noise spectral density in band | μV/√Hz typ. | 25 | 25 | 25 | 25 | 25 | 25 |
(0 ; 4000Hz) | max. | 27 | 27 | 27 | 27 | 27 | 27 |
Bias calibration | mg | <10 | <50 | <150 | <250 | <500 | <1000 |
One year bias stability@6000g | mg typ.(max.) | 1.5(<5) | 7.5(<25) | 22(<75) | 37.5(<125) | 75(<250) | 150(<500) |
Switch on/off repeatability | mg max. | <0.15 | <0.75 | <1.5 | <3.8 | <7.5 | <15 |
Bias temp. coefficient | mg/℃ typ. | <0.1 | <0.5 | <1.5 | <2.5 | <5 | <10 |
| mg/℃ max. | ±0.4 | ±2 | ±6 | ±10 | ±20 | ±40 |
Scale factor sensitivity(K1) | mV/g | 1000±8 | 200±2 | 66.6±1 | 40±1 | 20±1 | 10±1 |
One year scale factor stability | ppm typ.(max.) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) | 300(<1000) |
Scale factor temp. coefficient | ppm/℃ typ. | 100 | 100 | 100 | 100 | 100 | 100 |
| min./max. | -50/250 | -50/250 | -50/250 | -50/250 | -50/250 | -50/250 |
Input axis misalignment (Kp, Ko) | mrad max. | <10 | <10 | <10 | <10 | <10 | <10 |
| %max | 1 | 1 | 1 | 1 | 1 | 1 |
Resolution/Threshold(@1Hz) | mg max. | <0.1 | <0.6 | <1.7 | <2.8 | <5.5 | <11 |
Non linearity | % of FS max. | <0.8 | <1 | <1 | <1 | <1 | <1 |
| g max. | <0.02 | <0.09 | <0.27 | <0.50 | <1 | <2 |